FIELDLOGGER-HMI  Field Installable Display/Control Panel for FieldLogger Data Logger
FIELDLOGGER-HMI Installed in FieldLogger(purchased separately)
FIELDLOGGER-HMI Installed in FieldLogger(purchased separately)

FIELDLOGGER-HMI Field Installable Display/Control Panel for FieldLogger Data Logger

Regular price $210.00 Sale SKU:FIELDLOGGER-HMI
1 In stock* Ships in 3-4 weeks, if NOT in stock
* ships same or next day

  • Color 2.4” QVGA Screen
  • 96 X 48 mm Format
  • Indicates Channels Current Values as Text or Chart
  • Shows Fieldlogger Status and Alarm Information
  • Allows Viewing and Configuration of Some Parameters
  • Local or Remote Installation With RS485 Communication

The FIELDLOGGER-HMI is a field installable display/ keyboard for the FieldLogger data logger. The HMI has a color QVGA screen which can display the current channel value, history chart and status information. The HMI also allows to viewing and configuration of FieldLogger parameters via the keyboard.

The HMI is attached to the FieldLogger through a DB9 connector located under its cover. There is also the possibility of using the HMI remotely, attached to the FieldLogger through an extension cable.

Navigation between the screens is accomplished using the keyboard. There are six different screens, each one with a specific functionality, as follows:

FAVORITES SCREEN
This screen shows a six-position grid where you can assign a channel to be displayed in  each position. Each enabled channel in the FieldLogger is available for assignment.

CHART SCREEN
This screen shows a chart of the favorite channels’ logged values. The log starts when the HMI is powered and it is updated constantly, no matter which HMI screen is being watched.

CHANNEL LIST SCREEN
This screen shows a list with all FieldLogger enabled channels (analog, digital, remote, and virtual).

ALARMS SCREEN
The Alarms screen is 32-position grid of the FieldLogger alarms. Whenever an alarm is active, its number will be displayed in red on this screen.

STATUS SCREEN
On this screen, a list is shown with information about FieldLogger and the HMI  The following parameters can be monitored on this screen:
Firmware Version
Serial Number
Ethernet interface information
Interface enabled/disabled
Cable connected/disconnected
Cloud Status
Data Logger Information
  Scan Interval
  Logging Rate
  Storage Memory
  Free Memory,
  Logging Rate
  Logging Enable
  Storage Status

CONFIGURATION SCREEN
This screen allows for configuration of the following parameters.
Date configuration
Time configuration
Ethernet interface configuration
  DHCP enabling
  IP address configuration
  Subnet mask configuration
  Gateway address configuration
Modbus RTU interface configuration
  Operation mode: master/slave
  Modbus slave address
  Communication baud rate
  Communication parity
HMI configuration
  Time to turn the back light off
  "Chart" screen configuration

Compatible FieldLoggers: FLDLOG-485-ET-HMI, FLDLOG-24V-485-ET, FLDLOG-485-ET-HMI(bundled with HMI), FLDLOG-24V-485-ET-HMI(bundled with HMI)