- Small Size
- Most Reliable Non-Contact Temperature Sensor on Earth
- Self-Powered
- Intrinsically Safe
- Repeatability 0.02°F (0.01°C)
- Interchangeability +/-1%
- Resolution 0.0003°C (approx)
- Designed for OEM Use
Self powered micro IRT/C's are the most reliable non-contact temperature sensors in the market place. There are no active electronics so these passive thermocouple sensors can not fail.
Patented technology, the principle of operation of these sensors are calibrated to match conventional thermocouples at a specific temperature. By adjusting the calibration setting (c) of the IRT/C to equal the Seebeck coefficient (a), the signal output (mVout) will be within 2% linear to match the conventional thermocouple at a temperature close to the calibration point. As a result, when the Exergen IRT/C is wired into a conventional t/c input device, the target temperature (Tt) displayed will be the same as the surface (Ts).
IRt/c’s are pre-calibrated at the factory for typical target material emissive properties, but actual emissivities may differ. The accuracies specified assume that the precalibrated value is correct for your installation, or that the system has been calibrated at a single point for the application.
Target Temperature Variation | Error(greater of) |
0°F (0°C) | 0% or 0.02°F (0.01°C) |
±5°F (± 3°C) | ± 0.2% or 0.5°F (0.3°C) |
±10°F (± 6°C) | ± 0.4% or 1.0°F (0.6°C) |
±20°F (± 12°C) | ± 1% or 2°F (1°C) |
±40°F (± 24°C) | ± 2% or 4°F (2°C) |
±75°F (± 42°C) | ± 5% or 8°F (5°C) approx. |
±180°F (± 100°C) | > 5% or 8°F (5°C) |
To Order the models below scroll to the top of the page and choose the desired model from the "Models" drop down menu, then ADD TO CART |
PART NUMBER | TEMPERATURE RANGE, OUTPUT |
IR-EX-UIRT/C-K-440F/220C | 320-500°F, K thermocouple output |
IR-EX-UIRT/C-K-340F/170C | 280-370°F, K thermocouple output |
IR-EX-UIRT/C-K-280F/140C | 240-330°F, K thermocouple output |
IR-EX-UIRT/C-K-240F/120C | 180-250°F, K thermocouple output |
IR-EX-UIRT/C-K-180F/90C | 140-220°F, K thermocouple output |
IR-EX-UIRT/C-K-140F/60C | 70-190°F, K thermocouple output |
IR-EX-UIRT/C-K-80F/27C | 32-120°F, K thermocouple output |
IR-EX-UIRT/C-K-98.6F/37C | Human body range, K thermocouple output |
ACCESSORIES | |
IR-EX-APJ-1 | AIR & COOLING JACKET |
IR-EX-APJ-1-THRU-FITTING | PLASTIC FITTING W/LOCKNUT, SEALING NUT & HUB |
IR-EX-MB2 | MOUNTING BRACKET |
Down loads |
UIRT/C Data Sheet |
SPECIFICATIONS
Sensing Range: 0 to 975°F(-18 to 524C°) with linearization at readout
Ambient Temperature: -40 to 185F (-40 to 85C)
Minimum Spot Size: 0.1 (3 mm)
Spectral Response: 5.5 to 20μm
Output: K Type Thermocouple
Impedance: 17-45 KOhms, varies depending on temperature range
Emissivity: .90
Response Time: 50 millisecond time constant (typical)
Interchangeability: 1% to factory calibration conditions
Cable Assembly: 3 feet of unshielded, duplex insulated, type K, 24 AWC, PFA jacket rated to 500°F (260°C)
Housing: Stainless steel
Humidity: Non-condensing
Power: None, self powered
Sealed: Hermetically sealed, exceeds NEMA 4X, IP67
Weight: 1 oz. (30 grams) approximately
Dimensions: 0.25" (6.3 mm) Diameter x 1.0" (25.4 mm)
Input Device Compatibility: It is recommended to use input devices with less than 1nA of leakage current to minimize offsets and sensor break protection should be set to 40kohm maximum
FIELD of VIEW: 1:2 (110°) approximately.