- Designed for Temperature Measurement of Solid Surfaces
- Fast Response Time
- Temperature Range - 75°F to 350°F
- Adhesive Backing
- K and T Thermocouple, Special Limits of Error Grade Wire
The TC-SA is a thermocouple designed for the temperature measurement of solid surfaces. The sensor available in K or T thermocouple alloy consists of a beaded thermocouple joint which is machined flat to provide maximum surface contact and fast response time. The bead is mounted on a fiberglass cloth pad which has a silicone adhesive applied to it which allows the pad to be easily mounted to a surface. The thermocouple is rated to higher temperatures but the pad can be used to measure surfaces up to 350°F.
The TS-SA is available in 40 and 72 inch lengths.
Flat Junction Design
The junction of the TC-SA is manufactured using a proprietary welding process to form a flat bead which provides an excellent surface contact for exceptional accuracy.
New and Improved Version We are now offering a new and improved version of the TC-SA this new version offers:
|
To Order the models below scroll to the top of the page and choose the desired model from the "Pack Size" drop down menu, then ADD TO CART |
Model No. | Description |
TC-SA-K | Surface Thermocouple, Type K, 40 inches |
TC-SA-K-72 | Surface Thermocouple, Type K, 72 inches |
TC-SA-T | Surface Thermocouple, Type T, 40 inches |
TC-SA-T-72 | Surface Thermocouple, Type T, 72 inches |
SPECIFICATIONS
Thermocouple Wire: K or T Type with PTFE insulation, Special Limits of Error Grade
Wire Gauge: Type K 30 SWG (0.012" dia.), Type T: 24 SWG (0.022 "dia.)
Pad/Adhesive Temperature Rating: -60 to 177°C (-75 to 350°F)
Length (including pad): 40 or 72 inches model dependent
Response Time: < 100 ms (without pad)
Wire Termination: Stripped Leads
Accuracy*
T: +/-0.5°C or +/-0.4% of reading whichever is greater
K: +/-1.1°C or +/-0.4% of reading whichever is greater
* Accuracy of thermocouple element (use in application may impact accuracy)
Pad Materials
Pad: Fiberglass
Adhesive: Pressure sensitive silicone based
Dimensions
Pad : 3 x 2 cm (1.2 x .8 in) pad may be trimmed for user requirements
Thermocouple Lead Wire Length: 40 inches