FMT-25W Wall Mount Ultrasonic Transit Time Flow Meter

Free Shipping! - USA Orders Over $75

Customer Reviews
FMT-25W-AB and FMT-25-AE  Wall-mounted Transit Time Ultrasonic Flow Meters
FMT-25W-AB and FMT-25-AE Wall-mounted Transit Time Ultrasonic Flow Meters
FMT-25W-AB Ultrasonic Flow Meter with ABS Plastic Enclosure
FMT-25W-AB Ultrasonic Flow Meter with ABS Plastic Enclosure
FMT-25W-AE Ultrasonic Flow Meter with Aluminum Enclosure
FMT-25W-AE Ultrasonic Flow Meter with Aluminum Enclosure
FMT-25W-AB with Included Accessories
FMT-25W-AB with Included Accessories
FMT-25W-AE with Included Accessories
FMT-25W-AE with Included Accessories
FMT-25W-AB Rear View
FMT-25W-AB Rear View
FMT-25W-AE Rear View
FMT-25W-AE Rear View

FMT-25W Wall Mount Ultrasonic Transit Time Flow Meter

Regular price $1,090.00 Sale SKU:FMT-25W-AE-L
Ships in 3 weeks

  • Works with Most Liquids
  • Pipe Sizes From 1 Inch to 240 Inches (Transducer Dependent)
  • 4-20mA, RS485 and Open Collector and Relay Output
  • Positive, Negative and Net Totalizers
  • Programmable for Heat Flow Measurement (Requires Two PT100 Sensors)
  • Built in Alarm Buzzer
  • AC or DC Powered

The FMT-25W is a high-quality, low-cost transit time ultrasonic flow meter used to measure liquid flow in a full or closed pipe. The meter is designed with ease of operation, high accuracy and outstanding reliability. It can be used in a wide range of flow meter measurements including flow rate measurement of ultra-pure liquids, potable water, chemicals, raw sewage, reclaimed water, cooling water, river water, plant effluent, etc. Because the instrument and transducers are non-contacting and have no moving parts, the flow meter will not be affected by system pressure, fouling or wear. The included transducers are rated to 90°C. Higher temperatures can be accommodated with optional transducers (contact IOThrifty for more details).   With the use of two PT100 RTD sensors the FMT-25W can also measure heat flow.


Theory of Operation
The FMT-25W uses two transducers that function as both an ultrasonic transmitter and receiver. The transducers are clamped on the outside of a pipe at a specific distance from one another. The distance is calculated by the flow meter after entering pipe size dimensions and fluid properties.  The flow meter operates by alternately transmitting and receiving a modulated burst of sound energy between the transducers and measuring the transit time it takes for the sound to travel between the transducers.  The difference in transit time measured is directly and exactly related to the velocity of liquid in the pipe. The flow meter can report the flow rate as a velocity or convert it to volumetric flow rate units.

Analog, RS485 and Discrete Outputs
The FMT-25W includes several outputs including an analog current output, bi-directional RS485 and open collector and SPST relay.  The analog output is fully scalable and can be programmed to be either 4-20mA or 0-20mA. It will transmit a signal which linearly proportional to the flow rate, flow speed or heat flow.  The analog current output can also be controlled directly from an external device using the RS485 connection.  The FMT-25W also has bidirectional half duplex RS485 communications using MODBUS ASCII, MODBUS RTU or Fuji Extended Protocol.   The RS485 can be used to read all the measurement data as well as read or write the configuration parameters.   The RS485 port can also be connected to a printer to send measurement data at preset time intervals.  There is also an open collector and relay output.  Both of the outputs can be configured for several output options including flow rate alarms, signal quality alarms, batch control output and totalizer pulse.  The open collector output can also be configured for flow rate pulses.

Two Enclosure Styles
The FMT-25W is available in two base models with different form factors and enclosure styles.  The FMT-25W-AE is housed in a rugged cast aluminum enclosure very well suited for an industrial environment. The FMT-25-AB is more compact more economical version which is housed in a ABS plastic enclosure.  Other than the enclosure and form factor both flow meter versions have the same features and specifications.

Transducers for Pipe Sizes from 1 Inch to 240 Inches
The pipe size which the FMT-25W works with is determined by its transducer.  We offer transducers in 3 sizes; small transducer for pipe diameters 1 to 4 inches, medium transducers for pipe diameters 2 to 28 inches and large transducers for pipe sizes 12 to 240 inches. Each flow meter includes a pair of small, medium or large transducers.  Additional transducers are available for purchase and may be installed in the field.

Best Used with Relatively Clean Liquids with Full Pipes
For proper operation the flow meter requires a full pipe.  Also, since the flow meter measures flow rate by transmitting an ultrasonic signal between the two transducers, particulates in the liquid can obstruct the signal and impact the accuracy of the measurement.  Applications with liquids containing less than 50 ppm of particulates 50 microns or less in diameter are typically good applications for this transit time flow meter.  If your liquid contains higher amounts of particulates, please contact IOThrifty and we will be happy to discuss your application.

FMT-25W comes complete with:
1 ea. Wall Mounted Ultrasonic Flow Meter
2 ea. Clamp on Transducers (size is model dependent)
1 ea. Hexagonal Wrench
2 ea. Steel Clamps for mounting the transducer
1 ea. Acoustic Gel
1 ea. AC Power Cord

 Popular Models  - To order click on the model number (or scroll to the top of the page and choose the desired options from the drop down menus) then ADD TO CART

 Model Description
FMT-25W-AB-SIn Stock

FMT-25W Ultrasonic Flow Meter with ABS Enclosure and Small Transducers (1 to 4 inch pipe size)

FMT-25W-AB-MIn Stock FMT-25W Ultrasonic Flow Meter with ABS Enclosure and Medium Transducers (2 to 28 inch pipe size)
FMT-25W-AB-LIn Stock FMT-25W Ultrasonic Flow Meter with ABS Enclosure and Large Transducers (12 to 240 inch pipe size)
FMT-25W-AE-SIn Stock FMT-25W Ultrasonic Flow Meter with Aluminum Enclosure and Small Transducers (1 to 4 inch pipe size)
FMT-25W-AE-M FMT-25W Ultrasonic Flow Meter with Aluminum Enclosure and Medium Transducers (2 to 28 inch pipe size)
FMT-25W-AE-L FMT-25W Ultrasonic Flow Meter with Aluminum Enclosure and Large Transducers (12 to 240 inch pipe size)

 

Spare Transducers

 Model Description
FMT-25W-TS-2

Spare Small Transducers for FMT-25W, 1 to 4 inch pipe size

FMT-25W-TM-1 Spare Medium Transducers for FMT-25W, 2 to 28 inch pipe size
FMT-25W-TL-1 Spare Large Transducers for FMT-25W, 12 to 240 inch pipe size


 Downloads

FMT-25W Data Sheet

FMT-25W User Manual

 

SPECIFICATIONS

Main Unit Specifications
Principle: Transit-time
Accuracy: +/-1% of reading at rates >0.2mps
Linearity: 0.5%
Repeatability: 0.2%
Response Time: 0-999 seconds, user configurable
Flow Totalizers: 7-digit totals for net, positive and negative flow respectively
Display: LCD with backlight showing instantaneous flow rate, accumulated flow rate, fluid velocity, heat flow
Fluid Velocity: up to 32 m/s, bidirectional

Pipe Diameter (in)*

Maximum Flow

(GPM)

Minimum Flow (GPM)**

1

280

2

2

1,090

7

3

2,410

15

4

4,160

25

5

6,540

40

6

9,450

60

8

16,360

100

10

25,790

160

12

36,610

230

14

44,250

275

16

57,800

360

18

73,170

455

20

90,920

570

24

131,500

820

* Schedule 40 pipe
** Minimum flow is the lowest flow rate for which the FMT-25 will read flow at the rated accuracy.


Rate Units: Cubic Meter, Liter, USA Gallon, Imperial Gallon, Million USA Gallon, Cubic Feet, USA Liquid Barrel, Oil Barrel (Time can be per day, per hour, per minute or per second)
Inputs: Two PT100 temperature sensor for heat flow measurement, one 4-20mA
Output: One channel isolated 4-20mA or 0-20mA. Isolated RS485 output, one channel open collector output, one relay
RS485 Communication Protocol:  MODBUS ASCII, MODBUS RTU or Fuji Extended Protocol
Power: 8-36Vdc, 100-264 Vac 50/60HZ(FMT-25W-AE), 85-264 Vac 50/60HZ(FMT-25W-AB)
Power Consumption: Less than 1.5W
Temperature Range: -30°C to 90°C with standard transducers.  Up to 160°C with optional high temperature transducers.
Humidity: 85% RH
Protection Rating : IP65 for FMT-25W-AB(ABS enclosure), IP67 for FMT-25W-AB(aluminum  enclosure), Transducers have IP65 rating

Transducer Specifications
Pipe Size: 1 to 240 inches transducers dependent (small: 1-4 in., medium: 2-28 in., large: 12-240 in.)
Cable Length: 15 Ft
Protection Rating: IP65

Pipe/Liquid Specifications
Pipe Material: Standard entry for Carbon Steel, Stainless Steel, Cast Iron, Ductile Iron, Copper, PVC, Aluminum, Fiberglass-Epoxy, other pipes by entering material sound speed
Liquids: Direct entry for water, salt (sea) water,  kerosene, gasoline, fuel oil, crude oil, liquid propane, butane, diesel oil, castor oil, peanut oil, alcohol, other liquids supported by entering sound speed and viscosity

Reviews