- Infrared Thermocouple IRt/c
- K Thermocouple output
- Non-contact
- Self-powered
- Intrinsically Safe
- Repeatability 0.02 °F (0.01°C)
- Interchangeability +/- 1%
- Resolution approx 0.0003°C
- Small Size
uIRt/c.SV is a micro sized non-contact infrared type k thermocouple that reads at a right angle. It has a 1:2 field of view, stainless steel body and it's self-powered so no additional power source is required for use. The low price makes this an ideal option for OEMs.
IRt/c’s are pre-calibrated at the factory for typical target material emissive properties, but actual emissivities may differ. The accuracies specified assume that the pre-calibrated value is correct for your installation, or that the system has been calibrated at a single point for the application. The calibration temperature is included in the part number, for example the uIRt/c.SV-K-440F/220C is calibrated at 440°F. The error of this sensor at 10°F away from the 440°F, that is 430 or 450°F would be ± 0.4% of reading (1.7°F at 430°F)
Target Temperature Variation | Error(greater of)* |
0°F (0°C) | 0% or 0.02°F (0.01°C) |
±5°F (± 3°C) | ± 0.2% or 0.5°F (0.3°C) |
±10°F (± 6°C) | ± 0.4% or 1.0°F (0.6°C) |
±20°F (± 12°C) | ± 1% or 2°F (1°C) |
±40°F (± 24°C) | ± 2% or 4°F (2°C) |
±75°F (± 42°C) | ± 5% or 8°F (5°C) approx. |
±180°F (± 100°C) | > 5% or 8°F (5°C) |
* percent of reading
To Order click on the model no.(or scroll to the top of page and select field of view) then click the ADD TO CART button |
MODEL NUMBER | TEMPERATURE RANGE |
uIRt/c.SV-K-440F/220C |
320-500°F (160-260°C) |
uIRt/c.SV-K-340F/170C | 280-370°F (140-190°C) |
uIRt/c.SV-K-280F/140C | 240-330°F (115-165°C) |
uIRt/c.SV-K-240F/120C | 180-250°F (80-120°C) |
uIRt/c.SV-K-180F/90C | 140-220°F (60-105°C) |
uIRt/c.SV-K-140F/60C | 70-190°F (20-90°C) |
uIRt/c.SV-K-80F/27C | 32-120°F (0-50°C) |
uIRt/c.SV-K-50F/10C | 0-85°F (-18-30°C) |
uIRt/c.SV-K-98.6F/37C | Human Body Range |
Downloads |
uIRt/c.SV Spec Sheet |
SPECIFICATIONS
Sensing Range: 0 to 975 °F (-18 to 524 °C)
Ambient Temperature Range: -29 to 185 °F (-20 to 85 °C) permanent, -29 to 212 °F (-20 to 100 °C) non-permanent
Optimum Range Selections: Eight models per t/c type (see variants)
Field of View: Approximately 1:2 (110°)
Minimum Spot Size: .1" (3mm)
Spectral Response: 5.5 to 20μm
Output Impedance: 17-45 kohms approx
Response Time: 50 Milliseconds
Dimensions: See image above
Housing: Stainless steel, hermetically sealed, exceeds NEMA 4X, IP67
Cable: 3 feet of unshielded, duplex insulated, type K, 24 AWG, PFA jacket rated to 500 °F (260 °C) (Shielded cable available upon request)
Weight: Approximately 1 oz. (30 grams) with cable
Input Device Compatibility: It is recommended to use input devices with less than 1 nA of leakage current to minimize offsets and sensor brake detection should be set to 45 kohm maximum.