uIRt/c.SV Micro Size Infrared Thermocouple for OEMs with right angle 1

Free Shipping! - USA Orders Over $75

Customer Reviews
uIRt/c.SV Micro Size Infrared Thermocouple for OEMs with right angle 1:2 field of view, stainless steel body, K Thermocouple Output
uIRt/c.SV Micro Size Infrared Thermocouple for OEMs with right angle 1:2 field of view, stainless steel body, K Thermocouple Output

uIRt/c.SV Micro Size Infrared Thermocouple for OEMs with right angle 1:2 field of view, stainless steel body, K Thermocouple Output

Regular price $268.00 Sale SKU:uIRt/c.SV-K-440F/220C
Ships in 5 days

  • Infrared Thermocouple IRt/c
  • K Thermocouple output
  • Non-contact
  • Self-powered
  • Intrinsically Safe
  • Repeatability 0.02   °F (0.01°C)
  • Interchangeability +/- 1%
  • Resolution approx 0.0003°C
  • Small Size

uIRt/c.SV is a micro sized non-contact infrared type k thermocouple that reads at a right angle. It has a 1:2 field of view, stainless steel body and it's self-powered so no additional power source is required for use. The low price makes this an ideal option for OEMs.

IRt/c’s are pre-calibrated at the factory  for typical target material emissive properties, but actual emissivities may differ. The accuracies specified assume that the pre-calibrated value is correct for your installation, or that the system has been calibrated at a single point for the application.  The calibration temperature is included in the part number, for example the uIRt/c.SV-K-440F/220C is calibrated at 440°F.  The error of this sensor at 10°F away from the 440°F, that is 430 or 450°F would be ± 0.4% of reading (1.7°F at 430°F)

Target Temperature Variation Error(greater of)*
0°F (0°C) 0% or 0.02°F (0.01°C)
±5°F (± 3°C) ± 0.2% or 0.5°F (0.3°C) 
±10°F (± 6°C) ± 0.4% or 1.0°F (0.6°C) 
±20°F (± 12°C)  ± 1% or 2°F (1°C) 
±40°F (± 24°C) ± 2% or 4°F (2°C)
±75°F (± 42°C) ± 5% or 8°F (5°C) approx.
±180°F (± 100°C)  > 5% or 8°F (5°C) 

 * percent of reading

 

 To Order click on the model no.(or scroll to the top of page and select field of view) then click the ADD TO CART button
MODEL NUMBER TEMPERATURE RANGE
uIRt/c.SV-K-440F/220C 320-500°F (160-260°C)
uIRt/c.SV-K-340F/170C 280-370°F (140-190°C)
uIRt/c.SV-K-280F/140C 240-330°F (115-165°C)
uIRt/c.SV-K-240F/120C 180-250°F (80-120°C)
uIRt/c.SV-K-180F/90C 140-220°F (60-105°C)
uIRt/c.SV-K-140F/60C 70-190°F (20-90°C)
uIRt/c.SV-K-80F/27C 32-120°F (0-50°C)
uIRt/c.SV-K-50F/10C 0-85°F (-18-30°C)
uIRt/c.SV-K-98.6F/37C Human Body Range


 Downloads
uIRt/c.SV Spec Sheet

 

SPECIFICATIONS

Sensing Range: 0 to 975 °F (-18 to 524 °C)

Ambient Temperature Range: -29 to 185 °F (-20 to 85 °C) permanent, -29 to 212 °F (-20 to 100 °C) non-permanent

Optimum Range Selections: Eight models per t/c type (see variants)

Field of View: Approximately 1:2 (110°)

Minimum Spot Size: .1" (3mm)

Spectral Response: 5.5 to 20μm

Output Impedance: 17-45 kohms approx

Response Time: 50 Milliseconds

Dimensions: See image above

Housing: Stainless steel, hermetically sealed, exceeds NEMA 4X, IP67

Cable: 3 feet of unshielded, duplex insulated, type K, 24 AWG, PFA jacket rated to 500 °F (260 °C) (Shielded cable available upon request)

Weight: Approximately 1 oz. (30 grams) with cable

Input Device Compatibility: It is recommended to use input devices with less than 1 nA of leakage current to minimize offsets and sensor brake detection should be set to 45 kohm maximum.