- Precise dew point measurement down to -112 °F (-80 °Ctd)
- Quick response time
- 3.5" graphic display with easy operation via touch screen
- Integrated data logger for storage of measured values (up to 100 million points)
- USB interface for data transfer via USB stick and evaluation via CS Basic software
- Calculates various moisture parameters (lb/CF, mg/m³, ppm V/V, g/kg, °Ftd atm, % RH)
The DP 500 dew point meter offers robust and precise dew point measurement designed for mobile use across various demanding industrial environments. It's ideal for monitoring and analyzing the dew point in compressed air systems, or within the technical gases sector.
The DP 500 features a 3.5-inch touch screen display that not only shows real-time data but also facilitates easy navigation through menus and settings. It can also graphically display the dew point curve and the switching behavior of dryers over time, making it an ideal tool for system diagnostics.
The integrated data logger is capable of storing up to 100 million data points, which are crucial for historical analysis and trend detection. Data can be exported via USB stick and conveniently reviewed using CS Basic software for fast service reporting.
Industrial Compatibility
The DP 500 works seamlessly with a variety of sensors and can be easily adapted to any industrial setting thanks to its quick-coupling features and robust carrying case. Its precise calibrations offer reliability in moisture analysis, which is essential for maintaining the operational efficiency of air and gas systems.
Popular Models - To order click on the model number (or scroll to the top of the page and choose the desired options from the drop down menus) then ADD TO CART |
Part Number | Description |
DP-500 | Portable dew point meter with integrated data logger |
Downloads |
DP 500 Data Sheet |
DP 500 User Manual |
SPECIFICATIONS
Display: 3.5" touch screen
Measuring Range: Dew Point -112°F to 122°F (-80 °Ctd to 50 °Ctd)
Accuracy: ±0.5 °Ftd at 14…122 °F; Typ. ±2 °Ftd (further range)
Moisture Parameters: lb/CF, mg/m³, ppm V/V, g/kg, °Ftd atm, % RH
Pressure Range: Standard: -1…725 psi, Special: -1…5076 psi
Interface: USB interface
Data Logger: 16 GB SD memory card (up to 100 million values)
Power Supply: Output voltage: 24 VDC ± 10%, Output current: 120 mA in continuous operation
Battery: Internal rechargeable Li-Ion batteries, approx. 12 h continuous operation, 4 h charging time
Screw-in Thread: NPT 1/2” or G 1/2" stainless steel
Ambient Temperature: 14…122 °F
EMC: DIN EN 61326-1
Camera Key: Saves current screen as an image file. No additional software necessary.
Photo Key