- Frequency Read & Source Functions, Accuracy +/- 0.005% of Range
- Calibrate Totalizers, Output Pulses from 1 to 100 Minutes
- Gate Trigger Indicator, LED Flashes in Synch w/Output Frequency
- Full 5 Digit Display, True +/-0.005% of Range Accuracy
- EZ_Dial Knob, Push the Knob for Easy Change of Speed of Test Point
- EZ-Check Switch for Stop Watch Style Accurate Totalizer Measurements
- 240 VAC Tolerant for Fuse-less Protection From Misuse
- Superior Battery Life of 45 Hrs Under Typical Usage
- Comes with Manual, NIST Certficate, Carrying Case, CE Approved
The 541 is designed for calibration, testing and diagnosing turbine meters, frequency counters, vibration systems, tachometers, vortex shedders, integrators and any frequency device. Save hours of time compared to other calibration methods. When calibrating a totalizer, the 541 eliminates the need of a stop watch. Set the number of pulses and number of minutes required and it automatically stops when the selected number of pulses has been sent to the totalizer. The 541 has a handy LED indicator showing gate time for easy trigger level adjustment. The LED also pulses with the frequency output for calibration of optical pickups.
The 541 has 5 ranges from 1 CPH to 20.000KHz for source and read. Totalizer inputs/outputs are from 1 to 99999 pulses in 1.0 to 100 minutes, and read a wide range of frequencies and wave forms from 50 mV to 120V. The 541 can source sine and square waves with zero based or zero crossing and has an adjustable output amplitude from 100 mV to 12 V peak-to-peak.
To Order the model below scroll to the top of the page then click on ADD TO CART button |
PART NUMBER | DESCRIPTION |
CL-PI-541 | PIE 541 Frequency Process Calibrator w/Totalizer Function |
Datasheets and Operating Instructions |
SPECIFICATIONS
COMMON SPECS FOR ALL FREQUENCY MODES
Frequency range, 1 CPH to 20.000Khz
Accuracy, +/- 0.005% of range
Temperature effect, < 10ppm/C of range
FREQUENCY RANGE SPECS
1, 1 CPH< CPH range < 20000 CPH
2, 0.1 CPM (0.0167Hz) < CPM range < 2000.0 CPM (33.33Hz)
3, 0.01Hz < Hz < 200.00Hz
4, 0.1Hz < Hz range < 2000.0Hz
5, 0.001KHz < KHz < 20.000KHz
6, totalizer inputs/outputs from 1 to 99999 counts in 0.1 mins to 100.0 mins
READ INPUTS SPECS
Read, x1 attenuation range: 0.1Vpk to 12Vpk, x10 attenuation range: 1 Vpk to 120V peak - limit of attneuation is 120Vpk
Input impedance, > 1 Meg Ohm + 100pF
Adjustable signal attenuation, adjustable trigger level wit X1 and x10 attenuation ranges
Battery life, 24 hrs typical
Fuse-less protection, 240Vrms
WAVE FORMS SOURCES SPECS
Output current, > 6mApp at 12Vpp output, 20KHz
Output impedance, < 25Ohms
Square wave: zero crossing, zero based: selectable
Square wave: rise/fall time: < 0.0001% of output Vpk per second
Square wave: frequency jitter: < 0.5LSB of frequency range
Square range: duty cycle: 50% +/- 2%
Sine wave: offset and zero crossing symmetry: <+/- 10% of Vpk output amplitude setting
Sine wave: amplitude adjustment: 100mV < nominal output < 12Vpp +/-% of setting